Technical documentation
What institutional laundering does to a mattress encasement
Independent ISO 6330 testing on the fabric used in the BedBug Solution® Elite, what the results mean for a laundry that runs beds on a turnover schedule, and an honest account of what has not been tested yet.
The short answer. We do not publish a wash-cycle rating. We have not run a multi-cycle laundering test, and we will not quote a number we cannot show you the report for. What we can show you is measured dimensional stability, colour fastness and surface condition after laundering, plus a Lifetime Limited Warranty that covers the failure modes a cycle count is a proxy for.
The test
| Method | ISO 6330:2021 / ISO 3759:2011 / ISO 5077:2007 |
| Conditions | Procedure 4N, 40°C, tumble dry low, 3 wash cycles |
| Laboratory | SGS-CSTC Changzhou |
| Report number | SL42604312776801TX |
| Date | May 12, 2026 |
The results
Shrinkage is the result that matters most to a housekeeping operation. An encasement that shrinks stops fitting the mattress, and an encasement that does not fit gets left off the bed. At −0.6% lengthwise, an 80-inch queen loses under half an inch of length. Widthwise is the tighter number at −2.1%, which is why the Elite is cut with the stretch knit running across the mattress.
Colour change at grade 4 to 5 on the ISO grey scale means the change is between negligible and none. Negligible pilling matters for guest-facing properties, because a pilled encasement reads as worn even under a sheet and a pad.
View the full report, SL42604312776801TX (PDF)
What this test does not tell you
Three wash cycles at 40°C is a dimensional-stability test. It measures whether the fabric holds its size, colour and surface after laundering. It is not a service-life rating, and we are not going to present it as one.
An institutional laundry runs hotter than 40°C, typically 71°C or 160°F for healthcare disinfection, with alkaline detergent and mechanical extraction. A domestic-wash result does not speak to that process. Barrier-retention testing after repeated industrial laundering is in progress. Ask us for the current documentation before you write a specification.
On the cycle counts you will see quoted
Wash-cycle claims circulate in this category without a method attached. When you see one, three questions settle whether it means anything:
- Cycles of what? A cover can survive a wash and stop being waterproof. Ask what performance was retested afterwards, and against which standard.
- At what temperature? A cycle at 40°C and a cycle at 71°C are not the same event.
- Tested by whom, in what report? A number on a marketing page with no laboratory, no method and no report number is not a specification.
We would rather publish four measured results and tell you what is missing than publish one round number you cannot check.
What the warranty covers
Every BedBug Solution® Elite encasement carries a Lifetime Limited Warranty against seam failure, zipper failure and lamination failure. A cycle count is a proxy for exactly those three failure modes. The warranty is the commitment the number stands in for, and it does not expire at cycle 200.
Care specification
FILL IN BEFORE PUBLISHING
Wash temperature, dry setting, bleach and fabric-softener guidance, and inspection interval, taken from the Elite commercial specification sheet. Do not publish this page without them. A laundering page with no care instructions repeats the problem it exists to fix, and an unspecified care regime weakens a warranty claim.
About the tested material
The reports identify the tested article as "Spring/Sleepy's Knit + TPU," the laminated stretch-knit fabric used in the BedBug Solution® Elite encasement, tested on behalf of Bargoose Home Textiles through our manufacturing partner. Country of origin on the test report is China. Domestic manufacturing is available for contracts that require it, and we are happy to walk through which components are domestic and which are imported on a given order.
Related documentation, including ASTM F1670-08 fluid-barrier testing, 16 CFR 1610 flammability, OEKO-TEX certification and the Snell Scientifics bed bug reports, is on Test Reports & Lab Results.
Specifying encasements for a laundry operation?
Tell us your wash temperature, chemistry and turnover interval and we will send the current test documentation and a written care specification for your file.
Request documentation and bulk pricing
Or call (516) 255-1736, Monday to Friday 8:30 AM to 4:30 PM ET. Response within one business day.